How to Resolve Internal Valve Leakage

2026-10-09 13:39

Internal valve leakage is a hidden yet critical issue in industrial operations. After the valve is closed, the medium still seeps through the sealing surface. This not only wastes energy and loses materials but may also corrode equipment and create safety hazards.

1 (2).jpg

What is Internal Valve Leakage

Internal valve leakage occurs when sealing surfaces fail to mate fully upon valve closure. Media leaks from the high‑pressure side to the low‑pressure side through gaps. Unlike visible external leakage, internal leakage is hard to detect and often discovered only after equipment failure.

Root Causes

  • Sealing surface wear: Repeated cycling or hard particles in the medium scratch and wear sealing surfaces, breaking the seal.

  • Corrosion attack: Acids, alkalis and high‑temperature, high‑pressure process conditions gradually erode sealing materials, creating pores and grooves.

  • Improper installation and operation: Insufficient or excessive closing torque and installation misalignment impair sealing performance.

  • Incomplete actuator stroke: Misadjusted travel of electric or pneumatic actuators prevents full valve closure, leaving gaps between disc and seat.

Solutions

Traditional countermeasures rely on manual inspection and periodic part replacement. Manual checks have blind spots, and component replacement requires shutdowns, bringing obvious limitations. The HIVAL‑VilAct intelligent self‑leakage‑check, self‑compensating and self‑tightening valve better addresses customer demands. Built on an integrated “valve‑actuator‑cloud” architecture, it shifts from passive control to active management, combining autonomous and predictive maintenance to boost operational efficiency.智能阀.png

  • Internal Valve Leakage Detection Technology: Multi‑modal sensors continuously collect and analyze sealing condition data. With edge computing, it delivers millisecond‑level on‑line leakage judgement. Leakage detection sensitivity reaches 1% of rated system flow, with a false alarm rate below 1%.

  • Self‑compensating Shutoff Control Technology: Fuzzy PID algorithms dynamically adjust the motion profile of electric actuators. Following a closed  "detect‑compensate‑verify" loop, valve position auto‑correction is realized. The primary shutoff success rate rises to 98%, while impact from mechanical wear drops by 50%.

  • Edge Data Processing & IoT Access: An edge‑device‑cloud collaborative framework enables on‑site real‑time decisions and synchronizes key data to the cloud platform, supporting big‑data‑driven maintenance.

  • Cloud Equipment Platform: A universal cloud platform and client software support 4G/5G IoT access and multiple industrial protocols, delivering an advanced all‑in‑one edge‑cloud maintenance system.