Gate valves are used for full opening or full closing, as isolation valves, and not used as control valves.
The gate valve is closed (CTC) or opened (CTO) by rotating the valve stem clockwise, and the gate plate moves upward or downward through the valve stem thread.
Gate valves are suitable for applications requiring minimum pressure drop and a full-bore design. When fully opened, the unobstructed flow path ensures low pressure loss, and their full-bore configuration allows compatibility with pipeline pigging operations. The gate valve adopts the multi-turn threaded stem operation, which requires multiple rotations to fully open and close. Its slow actuation effectively prevents water hammer effect.
| Component Name | Material | ||||
| WCB/Trim 1 | WCB/Trim 5 | WCB/Trim 8 | CF8/304 | CF8M/316 | |
| Body | A216 WCB | A216 WCB | A216 WCB | A351 CF8 | A351 CF8M |
| Gasket | Soft Iron+Graphite or 304+Graphite | 304+Graphite | 316+Graphite | ||
| Seat | A105+13Cr | A105+STL | A105+STL | A351 CF8 | A351 CF8M |
| Trim | A105 WCB+13Cr | A216 WCB+STL | A216 WCB+13Cr | A351 CF8 | A351 CF8M |
| Stem | A182 F6a | A182 F6a | A182 F6a | A182 F304 | A182 F316 |
| Upper Sealing Seat | A182 F6a | A182 F6a | A182 F6a | A182 CF8 | A182 CF8M |
| Packing | Flexible graphite | ||||
| Bushing | A182 F6a | A182 F6a | A182 F6a | A182 F304 | A182 F316 |
| Screw | A193 B7 | A193 B7 | A193 B7 | A193 B8 | A193 B8M |
| Nut | A194 2H | A194 2H | A194 2H | A194 8 | A194 8M |
| Pin | ASTM A36 | ASTM A36 | ASTM A36 | 304SS | 316SS |
| Plate | A216 WCB | A216 WCB | A216 WCB | A351 CF8 | A351 CF8M |
| Bolt | A193 B7 | A193 B7 | A193 B7 | A193 B8 | A193 B8M |
| Nut | A194 2H | A194 2H | A194 2H | A194 8 | A194 8M |
| Bonnet | A216 WCB | A216 WCB | A216 WCB | A351 CF8 | A351 CF8M |
| Oil Cup | Carbon Steel | ||||
| Stem Nut | A439 D2 | ||||
| Gland Nut | Carbon Steel | ||||